年生產(chǎn)車間節(jié)能降耗措施計(jì)劃
年生產(chǎn)車間節(jié)能降耗措施計(jì)劃
":[{"c":{"ix":0,"iy":0,"iw":893,"ih":1263},"p":{"h":1263,"w":893,"x":0,"y":0,"z":1},"ps":{"_drop":1},"s":null,"t":"pic"},{"c":{"ix":0,"iy":1268,"iw":513,"ih":413},"p":{"h":413,"opacity":1,"rotate":0,"w":577.05,"x":135,"x0":135,"x1":135,"x2":712.05,"x3":712.05,"y":109.649,"y0":574.199,"y1":109.649,"y2":109.649,"y3":574.199,"z":2},"ps":null,"s":{"pic_file":"/home/iknow/conv//data//bdef//130713127//130713127_2_2.png"},"t":"pic"},{"c":{"ix":0,"iy":1686,"iw":503,"ih":400},"p":{"h":400,"opacity":1,"rotate":0,"w":565.95,"x":135,"x0":135,"x1":135,"x2":700.95,"x3":700.95,"y":584.999,"y0":1034.999,"y1":584.999,"y2":584.999,"y3":1034.999,"z":3},"ps":null,"s":{"pic_file":"/home/iknow/conv//data//bdef//130713127//130713127_2_3.png"},"t":"pic"}],"page":{"ph":1262.879,"pw":892.979,"iw":893,"ih":2086,"v":6,"t":"1","pptlike":false,"cx":0,"cy":0,"cw":892.979,"ch":1262.879}})
擴(kuò)展閱讀:節(jié)能降耗措施
節(jié)能降耗措施
水1、調(diào)整附樓衛(wèi)生間蹬位沖洗閥門的開啟度,使沖洗水流量合理、夠用。2、在酒店馬桶水箱內(nèi)安放礦泉水瓶,減少馬桶沖洗水的水量。
3、酒店各使用區(qū)域馬桶定期做是否有長(zhǎng)流水的檢查,杜絕漏水的現(xiàn)象。4、把員工餐廳的用水接入生活用水水表,降低用水成本。電
1、降低室內(nèi)溫度標(biāo)準(zhǔn),夏季控制在26-28度。
2、中央空調(diào)系統(tǒng)在小負(fù)荷時(shí)采用“單冷凍-單冷卻”的運(yùn)行模式,降低空調(diào)系統(tǒng)電能的耗用。
3、減少閥門,過(guò)濾器阻力,使中央空調(diào)系統(tǒng)系統(tǒng)處于良好的工況狀態(tài)。4、根據(jù)環(huán)境溫度情況實(shí)時(shí)、動(dòng)態(tài)運(yùn)行冷水機(jī)組,和各區(qū)域風(fēng)機(jī)。5、定期做好風(fēng)機(jī)盤管過(guò)濾網(wǎng)、翅片的清潔、保養(yǎng)工作。
6、縮短光彩燈飾系統(tǒng)的運(yùn)行時(shí)間:現(xiàn)19:00-23:00改為:20:00-22:00。
7、減少射燈、白織燈,提高節(jié)能燈的使用。
8、了解和采用新的節(jié)能技術(shù)和設(shè)備,如照明節(jié)電器等,達(dá)到節(jié)能的目的。9、凌晨2:00以后停用一部主樓客梯。
10、完善餐飲部、人力資源部、房務(wù)部部分水泵的過(guò)載保護(hù)裝置。氣
1、降低室內(nèi)溫度標(biāo)準(zhǔn),冬季控制在16-18度。
2、降低熱水鍋爐和采暖鍋爐的出水溫度。熱水鍋爐出水溫度42-46度,采暖鍋
爐出水溫度36-42度。
3、定期對(duì)鍋爐和燃?xì)庥镁哌M(jìn)行檢查維修,保證其良好的工況狀態(tài)。其它
1、部門發(fā)動(dòng)員工,共同做好節(jié)能工作,使全酒店形成良好的節(jié)能氛圍。2、部門明確專門的節(jié)能負(fù)責(zé)人,加強(qiáng)檢查監(jiān)督,嚴(yán)格管理,嚴(yán)格要求,做好巡視檢查記錄
酒店能耗費(fèi)用是酒店主要支出費(fèi)用之一,所以,降低能耗費(fèi)用是提高酒店GOP的重要舉措,是我們酒店運(yùn)營(yíng)關(guān)注的重點(diǎn)之一。在現(xiàn)有硬件標(biāo)準(zhǔn)情況下,分析酒店的運(yùn)行情況,建議酒店運(yùn)營(yíng)管理采取以下方法,進(jìn)一步完善酒店的節(jié)能降耗的舉措,以達(dá)到各酒店能耗的標(biāo)桿。客房部(客耗、洗滌、能源)1.回收低耗品做計(jì)劃衛(wèi)生時(shí)用;
2.續(xù)住房客人的低耗品不扔,垃圾袋反復(fù)使用,床上用品三天一更換;3.客房服務(wù)員打掃房間時(shí),隨手關(guān)閉不需要的電器設(shè)備(燈,電視等)4.清潔劑客房服務(wù)員稀釋后使用,污跡嚴(yán)重處方噴灑清潔劑5.禁止客房服務(wù)員打掃客房時(shí)使用熱水;
6.客房電視機(jī)的亮度調(diào)在合適位置,避免過(guò)亮;
7.客房服務(wù)員將退房客人未交還總臺(tái)的房卡套交總臺(tái)再利用;
8.將客人用過(guò)而不能在房間再次使用的卷紙回收放入公共衛(wèi)生間使用9.員工不是對(duì)客服務(wù)時(shí)嚴(yán)禁乘坐電梯;10.報(bào)廢布草的合理使用;11.回收廢品費(fèi)用定期處理;
12.會(huì)議室在客人使用完后,及時(shí)關(guān)閉空調(diào)燈光13.增加洗滌的回洗數(shù)量,降低洗滌成本.
前廳部(能源)
1.廣告燈、大廳燈光、前臺(tái)射燈(根據(jù)天氣情況分組開關(guān))-----當(dāng)班人員負(fù)責(zé);2.夜間時(shí),前臺(tái)電腦只保證登記和公安上傳錄入處于工作狀態(tài),其余關(guān)閉,隨時(shí)輪換;
3.對(duì)紙張的二次使用;
4.房卡套的房號(hào)等用2B鉛筆填寫以便反復(fù)使用;
5.保安巡視時(shí),關(guān)注大廳和樓層燈光的開啟是否按規(guī)定合理開啟,該關(guān)閉的,則隨手進(jìn)行調(diào)整;
工程1.每天巡視檢查鍋爐房、配電房
2.每日8:30抄水表、11:30抄電表,做好記錄;酒店管理人員詳細(xì)分析整體能耗變化,找出能源消耗的主要因素、發(fā)現(xiàn)不正常情況,及時(shí)改進(jìn)和提高能耗控制方法;
3.定期清洗水箱,做好排污工作,防止水結(jié)垢;
4.對(duì)二期恭桶水箱水位控制閥進(jìn)行調(diào)節(jié),減少?zèng)_水量;
5.客房出水點(diǎn)的出水溫度控制45度左右。應(yīng)根據(jù)季節(jié)變換、時(shí)段變換及時(shí)調(diào)整鍋爐燒水溫度。
6.定期對(duì)鍋爐進(jìn)行檢查維修,保證其良好的工作狀態(tài);
7.定期(一個(gè)月為宜)清洗所有空調(diào)過(guò)濾網(wǎng),以保持溫控效果;
8.夏、冬兩季開始時(shí),應(yīng)逐一檢查每個(gè)空調(diào)的制冷、熱效果,及時(shí)跟進(jìn)維修.9.養(yǎng)成良好習(xí)慣,人離檢查水電氣是否關(guān)閉;
酒店水電成本占營(yíng)業(yè)收入額的10%左右,節(jié)能增效是酒店運(yùn)行管理中的一大重要任務(wù)。酒店節(jié)能增效要從三方面著手:一是將節(jié)能增效上升到經(jīng)營(yíng)理念的層面來(lái)考慮,從源頭做起,即從新建或改造時(shí)就要考慮降低運(yùn)行費(fèi)用;二是日常經(jīng)營(yíng)中從小事、點(diǎn)滴做起,這樣必將收到良好的效果;三是制定全酒店月底、年底控制目標(biāo),對(duì)各部門進(jìn)行考核,實(shí)施績(jī)效分配機(jī)制,將節(jié)能效果與部門、個(gè)人業(yè)績(jī)和分配相結(jié)合,F(xiàn)將經(jīng)營(yíng)管理中節(jié)能增效措施75條提供給各部門糾正自身不足。1.有效管理的酒店運(yùn)行費(fèi)用低,經(jīng)營(yíng)利潤(rùn)高,反之亦然。2.節(jié)能理念最重要,從總經(jīng)理到每位員工要有成本經(jīng)營(yíng)理念;節(jié)省成本1元+經(jīng)營(yíng)額10元。沒(méi)有成本經(jīng)營(yíng)的酒店=無(wú)經(jīng)濟(jì)效益的酒店。3.功能布局合理是降低運(yùn)行費(fèi)用的最有效方法。
4.客房?jī)?nèi)布局適應(yīng)客人消費(fèi)理念,分三個(gè)區(qū)布局:過(guò)渡區(qū)(過(guò)道)、活動(dòng)區(qū)(窗口)、靜區(qū)(床),前兩個(gè)月用硬地面(瓷磚、木地板),后者可用軟地面(地毯),可減少PA清潔費(fèi)用。
5.客房衛(wèi)生間內(nèi)少用浴缸,多用淋浴。地面、墻面地磚可用彩色或迷彩色。6.客房?jī)?nèi)沙發(fā)數(shù)量可減少,不一定要“一個(gè)茶幾配兩張沙發(fā)”的老模式,可減少一個(gè)沙發(fā);少用全包式的沙發(fā),改用半包或全木式。7.減少或去掉一次性用品(六小件)。
8.如果當(dāng)?shù)刈猿嗨|(zhì)偏硬,布草不一定要用白色,可改用彩色布置。衛(wèi)生間地巾不一定用棉織品。
9.酒店餐廳、客房、康樂(lè)區(qū)域客用布草的尺寸、質(zhì)地按要求配置,尺寸不宜過(guò)大。
10.客房?jī)?nèi)采用通透式衛(wèi)生間,避免衛(wèi)生間長(zhǎng)明燈現(xiàn)象。11.衣櫥內(nèi)不設(shè)照明燈或彩用紅外感應(yīng)控制。12.設(shè)備應(yīng)定期維護(hù),保持良好的運(yùn)行狀態(tài)。
13.保持建筑物完好,防止不必要的滲漏,杜絕跑、冒、滴、漏現(xiàn)象。14.管道保溫層完好,厚度為50豪米。
15.更新耗能大的設(shè)備,避免電器超期服役。
16.嚴(yán)格管理:合理安排運(yùn)行,如冷凍機(jī)組、冷動(dòng)機(jī)組。
17.控制變壓器運(yùn)行臺(tái)數(shù),讓其工作負(fù)荷在60%-80%時(shí),效率較高。18.執(zhí)行工作程序,準(zhǔn)時(shí)抄表,監(jiān)視能源消耗。19.彩用取電牌控制客房用電設(shè)施。
20.照明系統(tǒng)彩用雙路以上控制,如公共區(qū)域、客房走廊的照明系統(tǒng)采用雙路以上控制。
21.采用新技術(shù)的半導(dǎo)體節(jié)能燈照明,節(jié)電70%。壽命延長(zhǎng)10倍。盡量使用節(jié)能燈照明,但要注意節(jié)能燈不要伸下“兩條腿”。
22.建筑物亮化彩用節(jié)能光源,亮化設(shè)施應(yīng)分區(qū)域、亮度,實(shí)行節(jié)日、平時(shí)可定時(shí)控制。
23.控制節(jié)能燈采購(gòu)程序,節(jié)省采購(gòu)費(fèi)用50%以上。24.及時(shí)去除電熱器具內(nèi)水垢。
25.用氣設(shè)備冷凝水回收可節(jié)約費(fèi)用20%-25%;冷凝水回到鍋爐房給水箱或洗衣房。
26.洗衣房、廚房等用蒸汽設(shè)備的疏水閥處于“疏水阻汽”狀態(tài),可節(jié)能10%。27.客房?jī)?nèi)不設(shè)飲水機(jī),用電熱水壺。
28.控制空調(diào)使用溫度夏季:22-260C;冬季:18-230C。夏季上升(冬季下降)10C,節(jié)省成本5%-8%。
29.酒店空調(diào)新風(fēng)系統(tǒng)工作正常可節(jié)省20%的能耗。大堂、餐廳、客房等前后臺(tái)區(qū)域的空調(diào)多用新風(fēng),不僅能改善空氣質(zhì)量,還能節(jié)能。30.空調(diào)系統(tǒng)每年清潔保養(yǎng)兩次可節(jié)省5%的運(yùn)行費(fèi)用。
31.酒店各區(qū)域空調(diào)耗能應(yīng)實(shí)行績(jī)效考核管理,裝分表控制,節(jié)能有獎(jiǎng)。32.酒店各區(qū)域(客房、廚房、洗衣房、員工更衣室、PA等)用水實(shí)行績(jī)效考核管理,裝分表控制,節(jié)能有獎(jiǎng)。
33.控制熱水溫度,夏季:45-480C;冬季:48-580C。水的溫度每上升10C,增加成本5%-8%。
34.控制冷、熱水壓力可節(jié)水5%,客房洗澡水壓力:0.2-0.3Mpa,如果是屋頂水箱供水應(yīng)解決客房頂層以下三個(gè)樓層供水壓力達(dá)到上述要求。
35.熱水系統(tǒng)應(yīng)有循環(huán)系統(tǒng),保證冬季客房混水器旋到左側(cè)時(shí),10-15秒內(nèi)應(yīng)出熱水;冷、熱水系統(tǒng)采用防銹管材,如紫銅管,綠色管材。
36.彩用熱水鍋爐比蒸汽鍋爐經(jīng)濟(jì),同時(shí)降低蒸汽鍋爐蒸汽壓力也可節(jié)能。37.增加熱水包體積可以上鍋爐夜間停止工作或減少工作時(shí)間。
38.餐廳(包廂)在開餐前15分鐘前使用新風(fēng)換氣、降溫,視客情調(diào)節(jié)空調(diào)溫度。
39.宴會(huì)廳、餐廳、餐廳包廂、大會(huì)議廳區(qū)域空調(diào)冷凍系統(tǒng)應(yīng)分區(qū)控制。40.酒店空調(diào)系統(tǒng)的主機(jī)應(yīng)按大、中、小搭配,避免“大馬拉小車”現(xiàn)象。
41.對(duì)分散式建筑的酒店(別墅區(qū)域)不一定使用中央空調(diào)系統(tǒng),可采用風(fēng)冷、分體、柜式等空調(diào)。
42.培養(yǎng)員工、客人科學(xué)的消費(fèi)理念。增訓(xùn)所有員工(從總經(jīng)理到員工)正確使用空調(diào)溫控器。少用高檔:控制中檔;使用低檔;如睡覺(jué)時(shí)溫度增加(夏季)或降低(冬季)1-20C,可節(jié)能5%-8%。
43.客房采用節(jié)水裝置,如調(diào)節(jié)水龍頭出水壓力,并用過(guò)濾網(wǎng),客用水符合三個(gè)要求:用水衛(wèi)生、水溫合適、壓力達(dá)標(biāo)。44.員工浴室采用水龍頭,用插卡噴淋頭。
45.管理程序應(yīng)改變,如餐廳當(dāng)晚的臺(tái)布當(dāng)晚洗,可節(jié)省洗滌成本10%以上,布草可延長(zhǎng)使用20-40次。
46.廚房用水“頭道不用新”分質(zhì)排放,可節(jié)水20-30%。
47.客房衛(wèi)生間沖水箱調(diào)節(jié)到6升,不用8升,每天可節(jié)省20升水,有條件可使用中水。
48.要使所有員工知道:酒店資金大進(jìn)大出,但不能大手大腳。從我開始,從點(diǎn)滴開始,如廢舊電器的再利用。再如大臺(tái)布可以做成小臺(tái)布,方臺(tái)布可做成長(zhǎng)臺(tái)布,舊布草可以做成洗衣袋以及遮塵套等,充分做到物盡其用。
49.在酒店大門入口處加防塵墊,寬度大于2米,可將60%的鞋底污垢擋在室外,減少大堂、樓層地毯PA清潔工作量。
50.酒店P(guān)A清潔應(yīng)記住“時(shí)間”是最好的去漬濟(jì)。任何污漬在6小時(shí)之內(nèi)處理是最有效的。
51.地毯保養(yǎng)方法:吸塵,局部及時(shí)去漬,控制洗滌。
52.花崗巖、大理石地面有污漬(口香糖)及時(shí)處理最有效,用油漆刮刀去除口香糖后,用洗滌濟(jì)再處理一下,就無(wú)痕跡了。
53.客房?jī)?nèi)布草可以一客一換,不必一天一換,但事先應(yīng)以提示牌征求客人意見(jiàn)。
54.加強(qiáng)物品領(lǐng)用制度,嚴(yán)格倉(cāng)庫(kù)管理。但應(yīng)注意以人為本。
55.教育員工養(yǎng)成良好的節(jié)能習(xí)慣,如上、下兩層樓自覺(jué)走步行梯。56.減少庫(kù)存量,由供應(yīng)商送貨。57.廚房原料進(jìn)價(jià)不定期詢價(jià),(起碼一周一次)降低采購(gòu)成本。58.倉(cāng)庫(kù)定期盤點(diǎn),幾物相符。減少漏洞。59.執(zhí)行好部門二級(jí)倉(cāng)庫(kù)領(lǐng)用、報(bào)損制度。
60.從源頭控制餐具破損率(倉(cāng)庫(kù)、餐桌、餐具柜)。新增加餐具應(yīng)視餐廳(包房)規(guī)格、數(shù)量采購(gòu),減少浪費(fèi)。
61.從源頭控制布草使用壽命,增加布草定餐廳、定客房類型、規(guī)格、數(shù)量采購(gòu),減少浪費(fèi)。
62.提高布草洗滌次數(shù)從源頭做起,餐桌收臺(tái)時(shí),減少菜肴湯對(duì)布草的污染,不要將硬物(牙簽等)夾在待洗的布草內(nèi)。減少客房?jī)?nèi)待洗布草二次污染機(jī)會(huì)(布草放在地面上、鞋印、運(yùn)往洗衣場(chǎng)的途中受污染)。干、濕洗之前要預(yù)先去漬,成功的洗滌取決于有效的預(yù)去漬,可有效地減少回洗。63.衛(wèi)生間內(nèi)排風(fēng)扇可去掉,改為屋頂集中式控制。
64.正確選用花崗巖和大理石,大堂地面、衛(wèi)生間臺(tái)面、窗戶等需要清潔的地方不用大理石,改用花崗巖。
65.電梯轎廂內(nèi)不用日期地毯,改為花崗巖地面。
66.大堂地面每天保養(yǎng)一次,保養(yǎng)時(shí)間夏季12點(diǎn)以后,冬季11點(diǎn)以后。67.洗衣設(shè)備安裝正確。用氣設(shè)備支管從主蒸汽管上方接入;用水設(shè)備支管從主水管下方接入。洗衣設(shè)備疏水閥型號(hào)要正確,大燙機(jī)用大容量(浮球式、倒吊桶式);其他設(shè)備用圓盤式。
68.洗衣房用水“頭道不用新”水洗排水分質(zhì)排放,可節(jié)水20%-30%。69.洗衣房工作時(shí)間可調(diào)整為夜班,用夜間的峰谷電。70.蒸汽、熱水管走地下時(shí)一定要懸空、保溫。71.洗衣房離鍋爐房不宜過(guò)遠(yuǎn)。
72.供廚房用的冷凍、冷藏庫(kù)體積應(yīng)合理配置。肉類原料化霜應(yīng)在冷藏室內(nèi)進(jìn)行,杜絕用自來(lái)水化霜。
73.灶臺(tái)用紅外(感應(yīng))控制式的,做到鍋離氣(油)關(guān)。用先進(jìn)的爐灶燃燒裝置。
74.公共區(qū)域多用自然光。
75.酒店內(nèi)部辦公指令傳遞采用無(wú)紙化(電腦網(wǎng)絡(luò));內(nèi)部文件用小號(hào)字體,紙張兩面都用。
1、用節(jié)水型的坐便器。用水分大解小解,引導(dǎo)客人正確使用?梢怨(jié)水一半以上。
2、逐步淘汰傳統(tǒng)的9升以上的坐便器改為6升型,或可以在水箱內(nèi)安裝節(jié)水芯,每只馬桶一年可節(jié)水30噸左右;蛴猛赁k法,每個(gè)水箱里放一個(gè)1.25升的可樂(lè)瓶,開房率×房間數(shù)×1.25升×平均使用次數(shù)=節(jié)水量。
3、員工浴室可安裝智能感應(yīng)式節(jié)水系統(tǒng)。刷卡洗澡男員工8分鐘,女員工12分鐘,控制用水量。
4、公共衛(wèi)生間可安裝感應(yīng)節(jié)水龍頭。
房間衛(wèi)生間可安裝流量節(jié)水龍頭,適當(dāng)控制水流量就可以節(jié)約1/3。5、中水回用。飯店可將部分廢水回收,經(jīng)沉淀過(guò)濾處理用于澆灌綠地、洗車、降溫……
6、國(guó)外不少飯店都有雨水收集系統(tǒng)。經(jīng)處理再利用,不讓資源白白流掉。
7、用提示卡引導(dǎo)客人,棉織品一日一換改為一客一換。
8、營(yíng)造節(jié)水的氛圍,用生動(dòng)的形式提示客人和員工。例如,國(guó)外有的飯店在房間放置提示卡:用一個(gè)杯子需要4杯水來(lái)清洗等。
9、對(duì)飯店的各個(gè)部門各個(gè)區(qū)域分別用水表計(jì)量。積累數(shù)據(jù)根據(jù)使用率額定合理的用水量。
10、建立制度,發(fā)動(dòng)員工養(yǎng)成良好習(xí)慣,加強(qiáng)對(duì)水電油氣跑冒滴漏的巡檢,杜絕長(zhǎng)明燈長(zhǎng)流水。據(jù)檢測(cè),國(guó)內(nèi)一般企業(yè)由于跑冒滴漏造成的浪費(fèi)在5%-10%。11、凝結(jié)水回收。蒸汽變成凝結(jié)水,水溫仍達(dá)70℃-80℃。每噸凝結(jié)水約含6公斤輕油燃燒的熱量。一家中型飯店一年可回收凝結(jié)水近5000噸。12、飯店的冷卻塔會(huì)形成大量的水霧。這不起眼的水霧,一家中型飯店一天就要飄掉60噸水,一年就要飄掉近5000噸水。可以通過(guò)改變氣流的角度,安裝收水器,即可大大降低水霧飄灑的損耗。13、采用新型節(jié)能光源。節(jié)能燈價(jià)格雖比傳統(tǒng)的白熾燈高數(shù)倍,但發(fā)光效率高45倍,使用壽命長(zhǎng)810倍,經(jīng)濟(jì)上完全可行。飯店如全部采用節(jié)能燈照明,至少可節(jié)電70%以上。況且節(jié)能燈的光譜色度現(xiàn)在已接近白熾燈,并不影響氛圍的烘托。
14、飯店大量的各類標(biāo)識(shí)指示燈、夜燈可采用發(fā)光二極管LED燈,每一個(gè)耗電不到1瓦。
15、走廊過(guò)道、消防樓梯宜采用感應(yīng)節(jié)能燈,防止出現(xiàn)長(zhǎng)明燈。國(guó)外有的飯店客人通道也采用感應(yīng)燈,只有客人前面的幾盞燈是亮的,人過(guò)燈滅。16、采用智能節(jié)電調(diào)壓開關(guān)系統(tǒng)。飯店的公共區(qū)域:大堂、會(huì)議廳、多功能廳、宴會(huì)廳等往往裝有數(shù)百個(gè)燈泡。此系統(tǒng)可根據(jù)日照條件和需要營(yíng)造的氛圍調(diào)節(jié)電壓和照射度?晒(jié)電20%左右。
17、組合式燈具可采用多開關(guān)分組控制。根據(jù)需要選擇不同的照明模式。18、在飯店工程設(shè)計(jì)規(guī)范中,對(duì)飯店耗電大戶:制冷機(jī)組、水泵、電梯、鍋爐、風(fēng)機(jī)等普遍留有30%的富余功率。在運(yùn)行中一般存在“大馬拉小車”的現(xiàn)象。采用變頻系統(tǒng),可根據(jù)溫度和負(fù)荷的變化調(diào)節(jié)電機(jī)的轉(zhuǎn)速頻率。一般可節(jié)電30%-50%,動(dòng)力電是飯店耗電的大頭,不到兩年均可收回設(shè)備的投資。19、因地制宜利用屋頂、墻面安裝太陽(yáng)能電池板,為飯店提供補(bǔ)充電源。20、我國(guó)的平均日照大于201*小時(shí)。新建的飯店可根據(jù)對(duì)建筑本身的優(yōu)化設(shè)計(jì),達(dá)到集取、存儲(chǔ)、分配太陽(yáng)能的功能。太陽(yáng)能熱水器、太陽(yáng)能采暖、太陽(yáng)能制冷、太陽(yáng)能取電等等。每平方米太陽(yáng)能板一年可節(jié)電800度,節(jié)省標(biāo)準(zhǔn)煤300公斤。
21、飯店戶外可采用太陽(yáng)能路燈、草坪燈、泛光燈、燈光指示牌等。22、日本有酒店采用太陽(yáng)能停車棚。既可為客人的車輛遮蔭免于暴曬,減少車子開空調(diào)的能耗和空氣污染,又為飯店提供電源。此類做法在技術(shù)上不存在問(wèn)題,關(guān)鍵在于理念。
23、防止濫用戶外輪廓燈和建筑射燈。既耗電又給客房和鄰人造成光污染。飯店的建筑泛光照明先進(jìn)的辦法是采用LED半導(dǎo)體燈。同樣的照明效果,卻可以節(jié)約75%的用電量。24、將空調(diào)的溫度設(shè)定在28℃。
友情提示:本文中關(guān)于《年生產(chǎn)車間節(jié)能降耗措施計(jì)劃》給出的范例僅供您參考拓展思維使用,年生產(chǎn)車間節(jié)能降耗措施計(jì)劃:該篇文章建議您自主創(chuàng)作。
來(lái)源:網(wǎng)絡(luò)整理 免責(zé)聲明:本文僅限學(xué)習(xí)分享,如產(chǎn)生版權(quán)問(wèn)題,請(qǐng)聯(lián)系我們及時(shí)刪除。